G.652.D
Standard single-mode fiber for broad network applications.
Mode Field Diameter (At 1310) - 8.6±0.4μm
Cladding diameter - 125±0.7μm
Core concentricity error - ≤0.5μm
Cladding non-circularity - ≤0.7%
Cut-off wavelength (λcc) (for cable) - ≤1260nm
Cut-off wavelength (λc) (for fiber) - 1180nm~1330nm
Primary coating diameter (Not included color layer) - 200±10μm
00Coating-cladding concentricity error - ≤12.0μm
Fiber curl radius - ≥4m
Attenuation(fiber) -
At 1310nm ≤0.36dB/km
At 1550nm ≤0.22dB/km
Attenuation(cable) -
At 1310nm ≤0.4dB/km
At 1550nm ≤0.3dB/km
Macro bending loss -
Φ=30mm, 10turns at 1550nm ≤0.25dB
Φ=30mm, 10turns at 1625nm ≤1.0dB
Φ=20mm, 1turn at 1550nm ≤0.75dB
Φ=20mm, 1turn at 1625nm ≤1.5dB
Chromatic dispersion -
Within 1288~1339nm ≤3.5ps/nm·km
At 1550nm ≤18ps/nm·km
Zero dispersion wavelength - 1300~1324nm
Zero dispersion slope - ≤0.092ps/nm2·km
Amount of fiber
Max. no. of the fiber per tube
Tubes/Filler
*Nom. thickness of sheath (mm)
Diameter (Appr.) (mm)
Weight (Appr.) (Kg/km)
72
12
6/0
0.5
4.5
19
96
12
8/0
0.5
5.2
27
144
24
6/0
0.5
5.3
28
192
24
8/0
0.5
6.3
41
288
24
12/0
0.5
8.1
66
432
24
18/0
0.5
8.3
64
576
24
24/0
0.5
9.7
93
864
36
24/0
0.5
11.5
123
*Note:The minimum thickness of the sheath is 0.3mm.

ITEM
TEST METHOD
SPECIFICATION
Tensile performance IEC60794-1-21-E1
-Short-term load:1 × W -Time: 5 minute
-Loss change ≤0.1dB@1550 nm(after test) -No sheath damage